Key facts
ItemDetail
Dominant threadG1/2 (BSPP, ISO 228-1) parallel thread, 14 threads per inch and a major diameter of 20.955 mm, sealing on a washer or cone face rather than on the threads
North AmericaShower arms commonly carry 1/2 inch NPT tapered thread; the hose supply end or an adapter is the conversion point
Adapter setFour types, all G1/2 on the head side: S = M22.1 x 1.5, G = M21.3 x 1.5, K = M21.5 x 2, M = M22.1 x 1.75
US flow ruleA federal maximum of 2.5 gpm at 80 psi commonly applies; WaterSense is voluntary at 2.0 gpm or less (specification version 1.1); California applies 1.8 gpm
CanadaThe National Plumbing Code of Canada (2020 and 2025 editions) limits individual shower heads to 7.6 L/min, about 2.0 gpm; provinces adopt the code with their own amendments
EuropeNo single national flow ceiling for shower heads in the larger European markets; a water saving claim needs its flow and test pressure stated
The one mandatory scheme to plan earlyWaterMark certification plus WELS registration for Australia, which belongs in the first RFQ conversation; confirm the New Zealand route separately
Factory reference conditionsFlow tested at 0.3MPa for selected specifications; pre-packing water test normally run at 0.5MPa as the leak point check

Read the Thread, Not the Country

A thread designation carries three facts: nominal size, thread form, and whether the thread is parallel or tapered. G1/2 is parallel, from the BSPP family defined in ISO 228-1, with 14 threads per inch and a major diameter of 20.955 mm. It does not seal on the threads: the cone nut seats into the head inlet, and the hex nut compresses a washer against the mixer outlet.

1/2 inch NPT is tapered, and the taper is the point: the flanks interfere as the joint tightens, so the seal is made on the threads with tape or sealant. G1/2 and NPT share a nominal size and nothing else.

Japanese naming causes the most confusion on a first order. Current Japanese products commonly carry G1/2 at the hose connection. Japanese faucet documentation also uses the designation PJ, as in PJ1/2; LIXIL states that its shower connection is G1/2 and treats PJ1/2 as a compatible, equivalent designation, so it is not a tapered thread. Some mixers use maker specific threads, such as M22 x 2 on KVK fittings, W23 with 14 threads on MYM fittings and W24 with 20 threads on TOTO thick-hose mixers. Pack an adapter set and confirm against the actual faucet model.

ConnectionThread formWhere it is native or usedSealing and dimensions
G1/2 (BSPP, ISO 228)ParallelEurope, the UK, most of Asia, Oceania, Africa and Latin America; hand showers and hoses almost everywhereSeals on a rubber washer at the mixer end and a cone face at the head end; 14 threads per inch, major diameter 20.955 mm
1/2 inch NPTTaperedUnited States, Canada and Mexico shower arms; Gulf projects specified to United States standardsSeals on thread interference with tape or sealant; nominal 1/2 inch, not interchangeable with G1/2
PJ1/2 (Japanese faucet documentation)Parallel; treated by Japanese makers such as LIXIL as compatible with G1/2Japanese faucet and shower connections, alongside G1/2 on current productsConfirm against the faucet model; KVK, MYM and TOTO thick-hose fittings use M22 x 2, W23 and W24 threads that need an adapter
ZHONGHE adapter set (S, G, K, M)Metric parallel on the fitting side, G1/2 on the head sideLegacy and non standard fittings in any marketS = M22.1 x 1.5, G = M21.3 x 1.5, K = M21.5 x 2, M = M22.1 x 1.75

Thread by Market

The table below sorts markets by what the wall gives you and what the hand shower gives you. Almost everywhere the hand shower and the hose are G1/2, and the only real question is what happens at the wall.

Two rows repay a second look. Mexico follows United States practice at the arm while using G1/2 on hand showers and hoses. Colombia and the Philippines can carry both conventions in the same housing stock, so the conversion point is set per order.

MarketWall outlet or shower armHand shower and hoseConversion point
United States and Canada1/2 inch NPT tapered on shower armsG1/2Hose supply end or an adapter
Mexico1/2 inch NPT tapered, following United States practice; NOM-008-CONAGUA-1998 requires an NPT-compatible shower connectionG1/2Hose supply end or an adapter
United Kingdom1/2 inch BSP, the same parallel thread as G1/2G1/2None needed; check the riser rail diameter for slide holders
Germany, France, Spain, Italy, Netherlands, PolandG1/2 (BSPP, ISO 228) at the mixer outletG1/2None needed; check the riser rail diameter for slide holders
Russia and TurkeyG1/2, written as half an inch in local catalogsG1/2None needed; check the riser rail diameter for slide holders
United Arab Emirates and Saudi ArabiaG1/2 usually; 1/2 inch NPT on projects specified to United States standardsG1/2State whether the order is retail or project
India, Nigeria, South Africa, Australia1/2 inch BSP or G1/2G1/2None normally needed; S, G, K and M cover legacy fittings
JapanG1/2 on current products; maker specific fittings on older faucetsG1/2Adapter set normally packed with the head
South KoreaG1/2G1/2S, G, K and M for older apartment fittings
Vietnam, Thailand, Indonesia, Malaysia and SingaporeG1/2 (BSPP)G1/2Confirm the heater outlet where the head connects to a wall heater
Brazil, Chile, Argentina1/2 inch connectionsG1/2Confirm the wall fitting with the importer
Colombia and the PhilippinesBoth NPT tapered and BSP parallel in useG1/2 shipped by defaultConversion point specified per order

Flow Limits and Labels by Market

A flow limit is a legal ceiling. A flow label is a marketing permission with rules attached. Confusing the two is the most common mistake here, because a product can be entirely legal and still be unable to carry the label a retailer wants on the box.

Numbers only mean something with a pressure attached. ZHONGHE flow tests selected specifications at 0.3MPa (3 bar, about 43.5 psi), where water saving specifications have measured roughly 50 to 70 percent below comparable non water saving heads. Where a market rule names its own reference pressure, that is the condition the compliance figure has to be produced at.

Every row below is an orientation reference, not a legal opinion. Confirm the current requirement with your compliance adviser or customs broker before artwork is printed.

MarketMandatory flow ruleLabel or schemePractical note
United StatesA federal maximum of 2.5 gpm at 80 psi commonly applies; the Department of Energy's 2021 showerhead definition was repealed with effect from 15 May 2025EPA WaterSense, voluntary, at 2.0 gpm or less (specification version 1.1)California applies 1.8 gpm at 80 psi under Title 20, with all nozzles of a multi-nozzle showerhead counted together; confirm the current state rule
CanadaThe National Plumbing Code of Canada (2020 and 2025 editions) requires individual shower heads to limit flow to 7.6 L/min, about 2.0 gpmThe model code is adopted province by province, with local amendmentsConfirm the code edition in force in the destination province before setting the flow target
MexicoNOM-008-CONAGUA-1998 sets flow limits by pressure class, with 4 to 10 L/min in its table and 2 to 10 L/min for hand showers; adjustable heads must comply in every settingNOM conformity verified by accredited bodiesState the target flow together with the pressure it must be met at
United KingdomNo single national flow ceiling applies to shower headsThe Water Fittings Regulations govern the fitting itselfGravity systems can run near 0.1MPa, so specify a flow at a stated pressure
Germany, France, Spain, Italy, Netherlands, PolandNo single national flow ceiling appliesVoluntary water labels and retailer criteria apply only where a label or claim is usedState the flow with its test pressure, and check any regional or municipal water saving rule before launch
AustraliaWELS registration and labelling apply to showers sold in AustraliaStar rating driven by flow in litres per minuteThe band boundaries are set by the scheme; confirm the current band table before a star goes on artwork, and confirm the New Zealand rule separately
SingaporePUB, the national water agency, runs the Water Efficiency Labelling Scheme with mandatory and voluntary tiersCheck which tier currently covers showerheads before a label goes on artworkConfirm the current scope with PUB or your importer
JapanNo mandatory maximum is commonly applied節水 is a headline retail claimJIS standards cover faucet fittings and are commonly referenced for method rather than as a flow ceiling; confirm the applicable reference
South KoreaNo mandatory maximum is commonly applied절수 is a recognised selling pointThe figure has to be stated with its test conditions
Saudi Arabia and United Arab EmiratesWater efficiency rules and labels exist for sanitary fittings; whether a given shower head is in scope, and at what limit, is confirmed per productSABER against SASO requirements; ECAS in the EmiratesConfirm the current limit and label format with your conformity assessment body before artwork
India, Brazil, South Africa, Nigeria, Vietnam, Thailand, Indonesia, PhilippinesNo mandatory shower flow maximum is commonly appliedNo efficiency label is usually requiredTank fed supply makes low pressure performance the real constraint rather than the ceiling

Water Fitting Schemes by Country

Schemes are granted for a product to an applicant, normally the brand or the importer, and not to a factory in general. ZHONGHE supports an application with samples, drawings and bills of materials, supplies component test reports, and arranges third party testing per project; certified options are available on request.

One entry differs in kind. WaterMark is mandatory in Australia for the plumbing and drainage products it covers, so it belongs in the first RFQ conversation; New Zealand has its own building rules, so confirm that route separately. For North American programs, the US and Canada importer page sets out the NPT and flow points together. Everything else is either a wetted material question answered by the bill of materials, or an import route the importer runs.

MarketScheme or routeWhat it covers
United StatesNSF/ANSI 61 and 372; cUPC or IAPMO listing; California Proposition 65Wetted materials and lead content; wholesaler and code listings; a warning duty on the party placing the product on the market
CanadaCSA B125.1 and ASME A112.18.1; cUPC or CSA listingReferenced by the National Plumbing Code; bilingual English and French labelling is commonly required
United KingdomWRAS approval or an equivalent Regulation 4 route; BS EN 1112 and BS EN 1113Water fittings connected to the supply; shower outlets and hoses
Germany, Austria, SwitzerlandDVGW, with ÖVGW in Austria and SVGW in Switzerland; KIWA as a further route; UBA material recommendationsDrinking water fittings and wetted materials
FranceACS, the attestation de conformité sanitaire; the NF mark as a voluntary routeMaterials in contact with drinking water
Netherlands and BelgiumKiwa and BelgaquaProducts in contact with drinking water
SpainAENOR against UNE-EN 1112 and UNE-EN 1113, voluntaryProduct conformity; the Código Técnico de la Edificación governs installation
ItalyUNI EN 1112 and UNI EN 1113, plus national rules on materials in contact with drinking waterShower outlets, hoses and wetted parts
PolandA hygienic attestation from the national public health institute; PN-EN 1112 and 1113Products in contact with drinking water
Russia and the Eurasian Economic UnionEAC mark on a declaration or certificate; GOST standards referencedSanitary products across Russia, Belarus, Kazakhstan, Armenia and Kyrgyzstan
TurkeyTSE mark or TS EN 1112 and TS EN 1113 test evidenceDistributor and public tender requirements; imports screened at customs
United Arab EmiratesECAS, with the Emirates Quality Mark as the higher tierRegulated products; municipality approval can apply on building projects
Saudi ArabiaSASO requirements shown through the SABER platformA product certificate of conformity, then a shipment certificate issued before arrival
AustraliaWaterMark certification plus WELS registrationPlumbing and drainage products installed in Australia; the flow label. Confirm the New Zealand route separately
IndiaBIS, the ISI mark and Quality Control OrdersA widening list of goods; confirm current coverage for your tariff line
BrazilINMETRO conformity schemesCompulsory programmes focus on electrical products such as the chuveiro elétrico
MexicoNOM conformity; NOM-050-SCFICommercial information on the label in Spanish
JapanJIS standards and the Water Supply Act frameworkFaucet fittings; leaching test methods for wetted materials
South KoreaKC certification; the Water Supply Act hygiene safety standard routeDesignated product categories and waterworks materials
Malaysia and SingaporeSIRIM and SPAN; the Singapore water utility approves water fittingsFittings used in the reticulation system; in Singapore, the WELS label where the product is in scope
Indonesia, Thailand, Vietnam, PhilippinesSNI and SPPT SNI; TISI; TCVN and QCVN; the BPS PS mark and Import Commodity ClearanceNational standards routes, mandatory for listed product groups
Nigeria, South Africa, EgyptSONCAP with Form M and PAAR; SABS and SANS with JASWIC listing; importer or brand registration with the national import authorityPre shipment certification and listings for water fittings

What to Put in the RFQ

Seven lines turn this reference into a buildable specification, and each changes the tooling, the bill of materials or the artwork.

  1. Name the wall fitting rather than the country: shower arm thread, mixer outlet thread, and whether the head screws directly to the wall.
  2. State the thread for each end of every item in the order, since a head, a hose and a holder can each carry a different one.
  3. Give a target flow with the pressure it must be met at, and name the reference condition your market rule uses.
  4. Say which label the product must be able to carry, because a label criterion is usually stricter than the legal ceiling underneath it.
  5. Name the scheme the destination requires and who will hold the approval, since it is granted to an applicant rather than to a factory.
  6. Decide which adapters ship in the box, and write the compatibility statement that will appear on the packaging.
  7. Confirm every rule quoted here with your own compliance adviser or customs broker before artwork goes to print, then send the list with a model photo through the RFQ page so the thread, flow target and adapter set are quoted together.

Sources and official references

Official pages for the standards and rules named above; requirements change, so confirm the current edition with the certifying body before ordering.